Shaanxi Hono Electronic Technology Co., Ltd.
+8617391768399
Contact Us

Introduction

When a laboratory process requires liquid delivery below 35 mL/min, the pump configuration and dispensing control become important selection factors. The HNBQ80S laboratory micro peristaltic pump covers a flow range of 0.0035–34 mL/min and offers two pump head configurations: DW10-1 for one channel and DW10-3 for three channels.

The pump combines adjustable speed, timed dispensing, external control, and RS485 communication. It can be considered for laboratory equipment, analytical instrument fluid handling, reagent dosing, and other systems that require controlled low-flow liquid transfer.

 
 

Technical Parameters

Parameter HNBQ80S
Flow range 0.0035–34 mL/min
Speed range 0.1–80 rpm
Speed resolution 0.1 rpm
Speed accuracy <±0.5%
Working time 0.1–999.5 Min/H/O
Dispensing interval time 0.1–999.5 Min/H/O
Dispensing time 1–999 sec; set to 0 for infinite loops
External control Start/Stop: passive contact; external control input level (5–24V)
Forward/Reverse: passive contact; external control input level (5–24V)
Speed regulation: configurable analog input, 0–5V / 0–10V / 4–20mA
Communication interface RS485 communication interface; MODBUS protocol available
Power supply AC 100–240V, 50/60Hz (power adapter included)
Power consumption <10W
Noise 60 dB
Working environment Temperature: 0–40°C; relative humidity: <80%
Dimensions (L × W × H) DW10-1: 152 × 112 × 107 mm
DW10-3: 164 × 112 × 107 mm
IP grade IP31

Pump Head Selection and Flow Configuration

Choose between one-channel and three-channel operation

The HNBQ80S is available with two listed pump head configurations. DW10-1 provides one channel, while DW10-3 provides three channels. The choice depends on the number of liquid lines required by the equipment or process.

Drive Type Pump Head Channel Tube Single Channel Flow Rate (mL/min)
HNBQ80S DW10-1 1 Wall 0.8–1 mm, Ds 3.17 mm 0.0035–34
DW10-3 3 Wall 0.8–1 mm, Ds 3.17 mm 0.0035–34

The stated flow parameters are based on transferring pure water with silicone tubing under normal temperature and pressure. Actual flow may be affected by operating conditions such as pressure and the liquid medium. The listed values are for reference.

Check the tubing dimensions against your setup

Both listed pump head options use tubing with a wall thickness of 0.8–1 mm and an inner diameter of 3.17 mm. The stated single-channel flow range is 0.0035–34 mL/min for each configuration.

Dispensing and Control Options

Set operating time and dispensing intervals

For processes that require repeated liquid additions rather than continuous operation, the HNBQ80S provides separate working-time, dispensing-interval, and dispensing-time settings. Working time and interval time can each be set from 0.1–999.5 Min/H/O. Dispensing time can be set from 1–999 seconds, with 0 used for infinite loops.

Operate locally or through external signals

The pump supports Start/Stop and Forward/Reverse control through passive contacts or an external control input level of 5–24V. Speed regulation can use a configurable 0–5V, 0–10V, or 4–20mA analog input. These options provide different ways to connect the pump to an equipment controller.

Connect through RS485 and MODBUS

An RS485 communication interface with MODBUS protocol support is available for systems that use serial communication. This is relevant when the pump needs to exchange control information with laboratory instruments or an automation system.

Monitoring and Operating Functions

Alarm functions for operating status

Locked-rotor and leakage alarms provide operating-status notifications. These functions are useful when the pump is installed in a process where unexpected interruption or liquid leakage needs to be noticed by the operator.

Mobile APP remote management

The product description lists optional mobile APP remote management and alarm notifications. A tubing lifespan reminder is also provided to help operators keep track of tubing replacement.

Local display and operation

The bilingual LCD provides access to operating settings. Local operation includes start/stop, direction reversal, full-speed operation, and speed regulation. Power-off memory is also listed among the control functions.

Applications

Laboratory and analytical equipment

The low-flow range and adjustable speed make the HNBQ80S suitable for laboratory liquid transfer, reagent dosing, and fluid handling in analytical equipment where controlled liquid delivery is required.

Environmental monitoring and water treatment

Timed dispensing and external control can be used in water sampling and chemical dosing setups. RS485 communication is available where the pump needs to be connected to monitoring or control equipment.

Fine chemical processes

The pump can be used for controlled liquid addition in fine chemical synthesis processes. The selected tubing and pump configuration should be assessed against the actual liquid and operating conditions.

New energy production equipment

External control and MODBUS communication provide connection options for production equipment requiring micro-dosing of liquid materials such as electrolytes and additives.

Dimensions (mm)

DW10-1: 152 × 112 × 107 mm

DW10-3: 164 × 112 × 107 mm

Frequently Asked Questions

How do I choose between the DW10-1 and DW10-3 pump heads?

Choose the DW10-1 when your equipment requires one liquid channel. Choose the DW10-3 when three channels are needed. Both configurations have a listed single-channel flow range of 0.0035–34 mL/min and use tubing with a wall thickness of 0.8–1 mm and an inner diameter of 3.17 mm.

Can the HNBQ80S handle intermittent dispensing instead of continuous pumping?

Yes. The controller provides separate settings for working time, dispensing interval, and dispensing duration. Working time and interval time are adjustable from 0.1–999.5 Min/H/O, while dispensing time is adjustable from 1–999 seconds. Setting dispensing time to 0 enables infinite loops.

What control signals are available for equipment integration?

The HNBQ80S supports passive-contact or 5–24V external Start/Stop and Forward/Reverse control. Speed regulation can use a configurable 0–5V, 0–10V, or 4–20mA analog input. An RS485 interface with MODBUS protocol support is also available for serial communication.

Request a Quote

To request a quotation for the HNBQ80S laboratory micro peristaltic pump, send us your target flow rate, required number of channels, tubing dimensions, and control interface requirements.

If you are replacing an existing pump or integrating the unit into laboratory equipment, you can also provide a product specification, equipment drawing, or sample image. Include your required quantity so we can review the requested configuration and prepare a quotation.

We are one of the most professional peristaltic pump manufacturers and suppliers in China, featured by quality products and good price. With abundant experience, we warmly welcome you to buy customized peristaltic pump made in China here from our factory. If you have any enquiry about quotation, please feel free to email us.

automatic dosing peristaltic pump, High Precision Microliter Peristaltic Pump, Laboratory Micro Peristaltic Pump

(0/10)

clearall